Mess hall elevation and sections for mobilization buildings in support of war efforts. They include front elevation for a 250 man mess hall, plan showing typical knee brace at walls, cross section, left end elevation, kitchen end elevation, half plan of louver, detail of built up corner, and section of kitchen entrance.
Mess hall floor plans for mobilization buildings in support of war efforts. They include a floor plan for 118 men, 170 men, 210 men, and 250 men. Other sections include a legend, electric fixture schedule, gas fixed heating cabinets, kitchen equipment, and general notes.
Mess hall plans for mobilization buildings in support of war efforts. They include Plan of Mess Hall for 250 Men Showing Plumbing and Electrical Layouts, Plan of Mess Hall for 210 Men, Framing Plan, Legend, Electric Fixture Schedule, Heating Cabinets, General Notes, and Kitchen Equipment.
Miscellaneous details for mobilization buildings in support of war efforts. They include d.h. window, detail of fixed window guard, detail of hinged window guard exterior, detail of hinged window guard interior, horizontally sliding window, exterior door detail, sliding door, interior door detail, sidewall section at water table, detail of shelf and mirror, concrete door sill, concrete pier for footing, porch door, details for recessed radiation, detail of wall framing and fire protection at heater room breaching and smoke pipe, typical section thru foundation wall and footing, and notes.
Miscellaneous sections for mobilization buildings in support of war efforts. They include d.h. window, detail of fixed window guard, detail of hinged window guard exterior, detail of hinged window guard interior, horizontally sliding window, exterior door detail, sliding door, interior door detail, sidewall section at water table, detail of shelf and mirror, typical details for insulation in exterior walls & first floor construction, concrete door sill, concrete pier & footing, porch door, details for recessed radiation, detail of wall framing and fire protection at heater room breaching and smoke pipe, typical section thru foundation wall and footing, and general notes.
Miscellaneous sections for mobilization buildings in support of war efforts. They include d.h. window, detail of fixed window guard, detail of hinged window guard exterior, detail of hinged window guard interior, horizontally sliding window, exterior door detail, sliding door, interior door detail, sidewall section at water table, detail of shelf and mirror, typical details for insulation in exterior walls & first floor construction, concrete door sill, concrete pier & footing, porch door, details for recessed radiation, detail of wall framing and fire protection at heater room breaching and smoke pipe, typical section thru foundation wall and footing, and general notes.
Miscellaneous sections for mobilization buildings in support of war efforts. They include d.h. window, detail of fixed window guard, detail of hinged window guard exterior, detail of hinged window guard interior, horizontally sliding window, exterior door detail, sliding door, interior door detail, sidewall section at water table, detail of shelf and mirror, typical details for insulation in exterior walls & first floor construction, concrete door sill, concrete pier & footing, porch door, details for recessed radiation, detail of wall framing and fire protection at heater room breaching and smoke pipe, typical section thru foundation wall and footing, and general notes.
Miscellaneous sections for mobilization buildings in support of war efforts. They include d.h. window, detail of fixed window guard, detail of hinged window guard exterior, detail of hinged window guard interior, horizontally sliding window, exterior door detail, sliding door, interior door detail, sidewall section at water table, detail of shelf and mirror, typical details for insulation in exterior walls & first floor construction, concrete door sill, concrete pier & footing, porch door, details for recessed radiation, detail of wall framing and fire protection at heater room breaching and smoke pipe, typical section thru foundation wall and footing, and general notes.
Plumbing details for mobilization buildings in support of war efforts. They include hot water heater connections to range boiler or vertical h.w. storage tank, hot water heater connections for horizontal h.w. storage tank, connections for vertical h.w. generator, gas hot water heater connections for h.w. storage tank, pipe stand for vertical hot water storage tank, method of installing range boilers in battery, schedule for hot water tank connection & accessories, lavatories in battery, wall hung urinal, front elevation through urinal, front elevation service sink, front elevation single or double compartment cement laundry tray, shower & drain, scullery sinks, water service box, cold water supply for pipe protection with shut off valve & drain, front elevation of wash sink, water closet, schedule for pipe covering, and notes.
This dialog allows you to filter your current search.
Each of the Months listed note their name and the number of records that will be limited down to if you choose that option.
This dialog allows you to filter your current search.
Each of the Days listed note their name and the number of records that will be limited down to if you choose that option.